Frequently Asked Questions
![]()
We have recently heard of hybrid Woodlyn instruments. Our equipment with other manufacturers’ parts on it- usually purchased from used equipment dealers. In that instance we are unable to assist with servicing as it is no longer a factory-spec Woodlyn instrument.
Please contact Woodlyn at 847.952.8330 and ask for your nearest repair technician. Some instruments you may wish to send into us directly, then a Return Authorization is required. All unknown packages will be refused.
Product: Chair
Q: My chair will not go up.
A: Make sure the top toggle on the foot control is leaning to the left.
Make sure the SL Arm lever is not stuck or activated.
Q:
The chair will recline, but will not go up
A: Same as above
Q: The footrest is tilted upward and will not come down.
A: Press down on the horizontal bar on the patients left, this will release the lock.
Product: Stand
Q: Nothing electrically works.
A: Check the fuses.
Q: My Refractor arm is too short.
A: Check the positioning of the Chair and Stand.
Product: Slit Lamp
Q: The bulb blew.
A: Order a replacement bulb, make sure not to touch halogen bulbs (it will reduce bulb life).
Q: Visual difficulties using the microscope head.
A: Put the focusing rod in, open the slit and aperture all the way and adjust each eye independently.
NOTE: the scale is a reference, not a prescription value.
Now as you try smaller apertures, you should see one image.
Q: What bulb does my slit lamp take?
A: ALL HR slit lamps can accept the 45070. Some HR series had a red base adapter which uses a 450012. Only a few HR series had a red base and a blue bulb 450013. Very few HR series had a black base which uses a 45006.
SMM series with the bulb mounted on the side (bullet style with flange) is 45470.
SMM series with a brass disk and 2 prongs is a 45570.
Product: R-900
Q: The Calibration is off.
A: How old is prism? Replace if worn or max 1 year.
Check Tonometer with Calibration tool.
Check the SL Eyepiece for correct focus.
Check SL for Level.
If the unit is still off, send into Woodlyn for Recalibration.
Product: Keratometer
Q: The Calibration is off.
A: Check the eyepiece focus.
Check the unit with a Lenscometer.
Product: Refractor
Q: How often should I have the unit serviced?
A: Every 1 to 2 years, Check the occulder from the patients side for how much build up. Use of the face shields with the lenses will greatly decrease the frequency.
Q: The lenses fog up easily
A: Apply a no fog product to the faceshield.
Q: The rotation lock will not and it is wobbily
A: A timely repair is suggested, must send in to be serviced.
Service: Loaners
Q: Do you have loaner instruments?
A: We only loan refractors, and it is on a first come basis.
We provide the instrument as a courtesy. Customers are required to handle all shipping costs. Shipping costs vary.
Service: Warranty Coverage
Q: What does my warranty cover?
A: All Woodlyn products are covered for one year parts and labor on manufacture defects only. Click Here to download our full warranty.
Q: Is there a warranty on service?
A: Yes, for 30 days on the original repair issue.
Q: How do I obtain software upgrades?
A: Contact woodlyn at 847.952.8330
Q: I am selling my practice. Can you help me value my Woodlyn equipment?
A: Woodlyn can help evaluate it, contact a Woodlyn Sales representative.
Q: I am thinking of buying a used piece of Woodlyn equipment. Can you tell me how old it is?
A: Age is one value, physical condition is another.
Chairs 658 series and Stands 148 series were made in 1984 ~ 90.
Chairs MN and MP were made in 1990 ~ 1999.
Stands SA were made in 1989 ~ 1991.
Stands SF were made 1991 ~ 2001.
Chairs V are made in 2000+.
Stands 2002 are made from 2001 and still in production.
Slit lamps with the hammer tone finish were made between 1984 and 1988.
Slit lamps s/ns 188 in '88.
189 in '89, 190 in '90, 191 in '91, 192 etc… until 204 in '04.
J is the series starting in '05 until present….numbers are now sequential.
Refractors s/ns 188 in '88.
189 in '89, 190 in '90, 191 in '91, 192 etc… until 204 in '04.
D is the series starting in '05 until present….numbers are now sequential.
Q: I purchased my Woodlyn equipment from another doctor. How do I go about servicing?
A: Please contact our service department for advice.
Q: What is the turn-around time for service?
A: Woodlyn repairs instruments on a first come basis, the severity of previous jobs dictates starting time of future jobs. If a client does not have a loaner, then his moves to the front as clients with loaners are not without a instrument.
Automated Equipment: Slit Lamp Camera
Q: The pictures I am taking aren't the same as what I am seeing, am I doing something wrong?
A: No. There are adjustments that can be made to enhance the image. Please refer to our guide on adjusting the camera settings located HERE.
Q: When should I use the diffuser?
A: The diffuser will evenly illuminate the anterior segment, however it also drastically reduced the brightness of the video stream. It is mainly used to get a full anterior segment photograph.
Automated Equipment: Canon CR-1 Mark II
Q: Why do I get black or white spots on all my pictures?
A: This is usually caused by dust particles residing on the CR-1's optics. Please call Woodlyn Inc. for assistance on removing dust particles from your CR-1 without damaging the optics.
Automated Equipment: E300 Topographer
Q: How often should I re-calibrate my E300?
A: To achieve the highest level of accuracy, we recommend re-calibrating your E300 every 6 months or every time you relocate the instrument. For a easy guide on how to calibrate your E300 click HERE.
Q: My computer freezes occasionally during an exam, what should I do?
A: Make sure you PC meets the basic requirements of the software. A graphics card with 256mb dedicated video memory is the minimum requirement for a PC operating an E300. Also, ensure the PC meets the basic requirements of the Medmont Studio software. For a list of these specifications, click HERE.
Automated Equipment: M700 Visual Field
Q: What do I do if I cannot see the fixation video stream?
A: Ensure the drivers for the M700 camera are properly installed. For a guide on troubleshooting the video camera drivers, click HERE.
Q: The patient response wand isn't working, what should I do?
A: Ensure that the plug going into your M700 is inserted fully into the receptacle. If it is inserted all the way, you may need to obtain a replacement wand. Please contact Woodlyn at 847-952-8330.
Automated Equipment: DV2000 Imaging Software
Q: How can I setup my software to work on multiple computers?
A: Please refer to our setup guide on how to configure a network installation of Medmont Studio. A copy of this guide can be accesses HERE.
Q: Does DV2000 integrate with any EMR software programs?
A: Yes. We are continually expanding the amount of Practice Management and EMR software programs that DV2000 will integrate with. For a comprehensive up-to-date list of which companies we integrate with, click HERE.